CONMOLY | CM-COAX-PS-LW | Lightweight Phase-Stable Coaxial Cables Shenzhen Xinju New Materials Technology Co., Ltd. https://conmoly.com Catalogue values support selection. Final tolerances, assembly performance and acceptance tests are defined in the approved drawing and specification. No certification is implied. Microwave coaxial cables using silver-plated bimetallic alloy in the centre conductor and mechanical protection layer, for weight-sensitive airborne and space equipment routing. Typical attenuation at +25 °C and sea level. Source test lengths: 10 m for CM-COAX-PS-LW-OD2P20; 20 m for the other four models. Compare mass for the same diameter and installation requirement; weight saving is not a fixed percentage for every model. Impedance: 50 Ω | All listed models Cutoff frequency: 18 GHz | Listed cable models Operating temperature: −55 to +125 °C | Finished cable Lightweight constructions Code | Centre conductor (mm) | Outer conductor (mm) | Overall diameter (mm) | Min. bend radius (mm) | Mass (g/m) | Capacitance (pF/m) | Cutoff frequency (GHz) CM-COAX-PS-LW-OD2P20 | 0.51 | 1.98 | 2.2 | 12.7 | 11.5 | 85 | 18 CM-COAX-PS-LW-OD3P60 | 0.91 | 3.05 | 3.6 | 25.4 | 23 | 80 | 18 CM-COAX-PS-LW-OD4P20 | 1.1 | 3.6 | 4.2 | 25.4 | 29.5 | 80 | 18 CM-COAX-PS-LW-OD4P82 | 1.37 | 4.35 | 4.82 | 25.4 | 40 | 80 | 18 CM-COAX-PS-LW-OD7P30 | 2.15 | 6.5 | 7.3 | 38.1 | 85 | 79 | 18 Lightweight constructions · typical attenuation (dB/m) Frequency (GHz) | CM-COAX-PS-LW-OD2P20 | CM-COAX-PS-LW-OD3P60 | CM-COAX-PS-LW-OD4P20 | CM-COAX-PS-LW-OD4P82 | CM-COAX-PS-LW-OD7P30 0.1 | 0.23 | 0.13 | 0.12 | 0.09 | 0.05 0.5 | 0.51 | 0.28 | 0.27 | 0.19 | 0.11 1 | 0.71 | 0.39 | 0.37 | 0.27 | 0.15 2 | 0.92 | 0.5 | 0.46 | 0.34 | 0.21 4 | 1.3 | 0.75 | 0.64 | 0.49 | 0.31 6 | 1.55 | 0.94 | 0.78 | 0.6 | 0.38 8 | 1.8 | 1.05 | 0.89 | 0.7 | 0.44 10 | 2.05 | 1.15 | 1 | 0.78 | 0.5 12 | 2.25 | 1.3 | 1.1 | 0.86 | 0.55 14 | 2.45 | 1.4 | 1.2 | 0.93 | 0.61 16 | 2.55 | 1.5 | 1.27 | 1 | 0.64 18 | 2.75 | 1.6 | 1.35 | 1.06 | 0.68 Typical attenuation at +25 °C and sea level. Source test lengths: 10 m for CM-COAX-PS-LW-OD2P20; 20 m for the other four models. Compare mass for the same diameter and installation requirement; weight saving is not a fixed percentage for every model. Lightweight constructions: CM-COAX-PS-LW-OD2P20 · CM-COAX-PS-LW-OD3P60 · CM-COAX-PS-LW-OD4P20 · CM-COAX-PS-LW-OD4P82 · CM-COAX-PS-LW-OD7P30 Centre conductor: Silver-plated bimetallic alloy centre conductor; the mechanical protection layer also uses silver-plated bimetallic alloy. Dielectric: Low-density PTFE insulation. Outer conductor and shield: Silver-plated flat conductor and braided shield. Jacket: Fluoroplastic jacket. Signal and frequency: Protocol, frequency band, impedance and loss budget. Installation: Length, routing, bend radius, motion and available space. Environment: Operating temperature and required environmental tests. Termination: Connector, pinout, shielding and strain relief. Impedance and attenuation at agreed frequency points Continuity, insulation resistance and dielectric withstand as specified Application-specific bend, temperature and assembly verification Antenna and equipment interconnects RF and microwave test systems Airborne equipment routing Cable supply or project-specific termination Confirm connector and cable compatibility before assembly Catalogue values support selection. Final tolerances, assembly performance and acceptance tests are defined in the approved drawing and specification. No certification is implied. Cable Product Manual · A1 · PDF pages 4, 9 Source: https://conmoly.com/resources