Cat6A Cable AWG Selection: Compare the Complete Construction

Published / updated:

AWG is one input to a Cat6A cable choice. The finished cable also includes insulation, pair arrangement, shielding and jacket. Select the equipment interface and installed route first, then compare the complete construction. CONMOLY’s current catalogue distinguishes base models from S02 variants; keeping the full code matters.

Compare the current base-model rows

The Ethernet cable page publishes these four base models. Diameter and mass columns are labelled as maxima. Preserve that basis when checking space and weight; do not silently turn a maximum into a typical value.

CodeConductor (AWG)Max. diameter (mm)Max. mass (g/m)
CM-CAT6A-4P-AWG30304.3530
CM-CAT6A-4P-AWG28285.459
CM-CAT6A-4P-AWG26266.253
CM-CAT6A-4P-AWG24247.569

Do not rank finished-cable mass by AWG alone. The listed construction data, rather than the gauge number, should control a comparison. Review the actual outside diameter against connector entry, backshell space and the installation route.

Treat S02 as a separate construction entry

ModelConductor (AWG)Temperature (°C)Maximum mass (g/m)
CM-CAT6A-4P-AWG24-S0224−25 ~ 8078.6
CM-CAT6A-4P-AWG26-S0226−25 ~ 8062.0
CM-CAT6A-4P-AWG28-S0228−55 ~ 20042.0
CM-CAT6A-4P-AWG30-S0230−25 ~ 80—

The S02 table has its own model-specific temperature and mass entries. Those temperature ranges must not be applied to all base models, and the base-model diameter column must not be reused as an S02 diameter specification. A missing value remains an enquiry item.

Keep detailed limits attached to the named model

The current model detail for CM-CAT6A-4P-AWG26 lists four pairs, a blue FEP jacket and diameter 6.00 ± 0.20 mm. Its 6.20 mm upper endpoint is consistent with the base table’s 6.2 mm maximum diameter; these are different presentations of a compatible dimension.

That named model’s detail also lists 100 ± 10 Ω impedance, nominal 43 pF/m capacitance, nominal 4.3 ns/m propagation delay, a 45 mm bend-radius entry and an engineering-use temperature range of −55 to +200 °C. Keep these entries attached to CM-CAT6A-4P-AWG26. They do not rate every AWG or S02 option, establish repeated-flex life, or prove environmental testing.

Specify the link, not just the cable label

  • Equipment and required Ethernet operating mode.
  • Installed length, connectors, termination and pair or shield arrangement.
  • Routing envelope, bend conditions and any movement.
  • Actual environmental exposure and the selected full model code.
  • Required sample evaluation and acceptance evidence for the assembled link.

Do not derive a supported link length or rate from conductor size alone. A project must identify the relevant system conditions and acceptance method. The data bus family chooser helps confirm that Ethernet is the correct family before an AWG comparison.

FAQ: Does AWG26 identify a unique Cat6A construction?

No. Keep the complete code and suffix. Base and S02 entries must be reviewed separately.

FAQ: Is a temperature entry evidence of a tested complete link?

It describes the named entry’s stated range. The connectors, assembled configuration and required test evidence still need review. See material and cable temperature distinctions.

FAQ: What should I send for an AWG comparison?

Provide the interface, length, connector drawing, route and environmental requirement through the contact page. State which limit is driving the choice: available space, mass, termination or electrical acceptance.