When Is Tape-Wrapped PTFE Cable Worth the Cost?
Assess tape-wrapped PTFE cable against RF, routing, mass and environmental requirements, with comparable evidence and a defined supply scope.

CONMOLY
Read cable selection guides and download bilingual basic specifications covering published dimensions, materials and model-specific entries.
Assess tape-wrapped PTFE cable against RF, routing, mass and environmental requirements, with comparable evidence and a defined supply scope.
Compare RF interconnects using published construction data, consistent loss conditions, routing constraints and a defined movement requirement.
Separate resin service temperature, cable specifications, sample results and assembly requirements when reviewing a PTFE-insulated cable configuration.
Define the interface, cable construction, electrical acceptance and environmental exposure needed to review a differential-pair or bus interconnect.
Plan separate RF phase evaluations for bending and temperature, with identified reference states, controlled conditions and traceable results.
Align replacement cable requirements, delivery scope, quotation inclusions and sample acceptance so that technical and commercial comparisons are traceable.
Compare CONMOLY’s lightweight, ultra-flexible and flexible 50 Ω coaxial cables by construction, dimensions and mass, with a model-specific selection example.
Understand phase stability versus phase matching, separate bending from temperature effects, and define a comparable RF cable assembly test.
Build a frequency-specific RF cable loss budget, distinguish cable and assembly data, and check the installed route before selecting a construction.
Prepare an RF cable assembly enquiry with connector details, length datum, routing, frequency requirements and a clear sample acceptance plan.
Specify VNA test cable interfaces, reference planes, bench movement and acceptance conditions before choosing a cable or armoured assembly.
Review lightweight coax cable mass, installed length, routing and assembly requirements for airborne antenna feeds without assuming qualification.
Choose the correct data cable family from the system interface, then compare construction, impedance, termination and environment for the specific model.
Compare current Cat6A base and S02 constructions by model, diameter, mass and temperature, without deriving link performance from conductor gauge.
Review IEEE 1394b cable construction, model-specific dimensions, impedance, temperature and system validation for an aviation application.
Compare published LVDS twisted and parallel pair constructions, keep drain variants distinct, and define connector, routing and signal requirements.
QUICK SERIES REFERENCE
Compare all 19 series with published model tables and bilingual PDFs. Select a series to view model-by-model outer diameters, conductor sizes and construction diagrams.
| Series & Code | Category | Models | Published basic specifications | Primary materials | Datasheet |
|---|---|---|---|---|---|
| Lightweight Phase-Stable Coaxial CablesCM-COAX-PS-LW | Communication Cables | 5 | Nominal impedance: 50 Ω | Conductor: Silver-plated copper-clad aluminium.; Dielectric: ePTFE / LD-PTFE.; Jacket: Fluoropolymer; FEP by default, with ETFE and other options according to environment. | PDF ↓ |
| Ultra-Flexible Phase-Stable Coaxial CablesCM-COAX-PS-UF | Communication Cables | 4 | Nominal impedance: 50 Ω | Centre conductor: Regularly stranded silver-plated centre conductor.; Dielectric: Low-density PTFE insulation.; Outer conductor and shield: Silver-plated flat conductor and braided shield. | PDF ↓ |
| Flexible Phase-Stable Coaxial CablesCM-COAX-PS-F | Communication Cables | 7 | Nominal impedance: 50 Ω | Centre conductor: Solid silver-plated centre conductor.; Dielectric: Low-density PTFE insulation.; Outer conductor and shield: Silver-plated flat conductor and braided shield. | PDF ↓ |
| Cat 6A Ethernet CablesCM-CAT6A-4P | Communication Cables | 8 | Nominal impedance: 100 Ω | Standard model constructions: Models without S02 suffix: silver-plated copper, ePTFE/PTFE insulation, individual foil shields and overall braid, fluoropolymer jacket.; Additional configurations: S02 jacket and shielding are specified per order; refer to the separate temperature and mass table. | PDF ↓ |
| Shielded Twisted-Pair CablesCM-STP | Communication Cables | 14 | Operating temperature: −55 ~ 200 °C · Nominal impedance: 100 Ω / 120 Ω | Conductor: Silver-plated copper or alloy, according to construction.; Dielectric: ePTFE / PTFE; Shield / jacket: Silver-plated copper braid / FEP | PDF ↓ |
| Phase-Stable RF Cable AssembliesCM-COAX-ASM-GP | Cable Assemblies | 10 | Nominal impedance: 50 Ω · Ordering: Select the cable configuration, connector at each end, length and tolerance. Dimensions below describe the cable, not an assembled connector. | Dielectric: Low-density PTFE; Conductor: Solid or stranded silver-plated conductor, by configuration.; Jacket: PFA, FEP or TPU, by configuration. | PDF ↓ |
| Armoured RF Cable AssembliesCM-COAX-ASM-TEST-RG | Cable Assemblies | 2 | Ordering: Connector pair, length and tolerance are specified per order. | OD6P50 protection: SUS304 spring, stainless-steel braid, FEP wraps and PTFE filament braid.; Base cable: Low-density PTFE insulated, shielded phase-stable coaxial cable. | PDF ↓ |
| IEEE 1394b Aviation Data-Bus CablesCM-1394B-SQ | Communication Cables | 5 | Nominal impedance: 110 Ω | Conductor: Silver-plated copper, star-quad construction.; Insulation: ePTFE / PTFE.; Shielding: Dual silver-plated copper braids. | PDF ↓ |
| HDMI CablesCM-HDMI | Communication Cables | 2 | High-flex construction: HDMI 2.0; −25 ~ 80 °C; minimum bend radius 6 × OD | High-flex signal pairs: Silver-plated copper alloy; ePTFE/PFA insulation; aluminium foil pair shields.; High-flex control conductors: 30 AWG (41/46), with Hytrel insulation.; High-flex overall shield / jacket: Tinned copper braid / black PVC. | PDF ↓ |
| USB 2.0 / USB 3.0 CablesCM-USB | Communication Cables | 7 | USB 3.0 OD5P20 / HF-OD5P20 temperature: −25 ~ 80 °C · Connector configuration: USB connector type, pin assignment and cable length are specified per order. | USB 3.0 OD5P20: FEP jacket; 26 AWG signal / power, 28 AWG USB 2.0 pair.; USB 3.0 HF-OD5P20: TPU jacket; 28 AWG signal, 30 AWG USB 2.0 pair, 22 AWG power. | PDF ↓ |
| GLink Bus CablesCM-GLINK-SQ | Communication Cables | 1 | Nominal impedance: 100 Ω | Conductors: Silver-plated copper strands.; Insulation: ePTFE / PTFE; low-density PTFE separating tape.; Shield: Silver-plated copper tape and braided conductor layers. | PDF ↓ |
| LVDS Differential CablesCM-LVDS | Communication Cables | 17 | Nominal impedance: 100 Ω | Conductors: Silver-plated copper; gauge and stranding vary by model.; Insulation: ePTFE / PTFE.; Shield and drain: Braided conductor or aluminium composite tape; drain wire by construction. | PDF ↓ |
| Low-Loss Microwave Coaxial CablesCM-COAX-LL | Communication Cables | 9 | Nominal impedance: 50 Ω | Dielectric: Low-density PTFE; solid PTFE for OD4P70.; Shielding: Metal tape and braided shielding; construction depends on model. | PDF ↓ |
| Precision Coaxial CablesCM-COAX-PREC | Communication Cables | 8 | Nominal impedance: 50 Ω; OD1P70: 51 Ω · Low-delay constructions: 4.3 ns/m (OD1P40 / OD1P80 / OD2P05) | Dielectric: ePTFE/FEP, FEP or low-density PTFE, depending on construction.; Shielding: Silver-plated copper tape and/or braid, depending on model. | PDF ↓ |
| Semi-Flexible Coaxial CablesCM-COAX-SF | Communication Cables | 6 | Nominal impedance: 50 Ω | S01 insulation / jacket: Fluoropolymer; Other constructions: Solid PTFE insulation; OD2P90 uses PVC jacket, other listed constructions use FEP. | PDF ↓ |
| Semi-Rigid Phase-Stable Coaxial CablesCM-COAX-PS-SR | Communication Cables | 4 | Nominal impedance: 50 Ω · Listed cutoff frequency: 40 GHz · Operating temperature: −65 ~ 250 °C | Centre conductor: Silver-plated copper alloy; Dielectric: Low-density PTFE; Outer conductor: Copper alloy | PDF ↓ |
| 1553B Data Bus CablesCM-1553B | Communication Cables | 1 | Impedance: 77 ± 5 Ω · Operating temperature: −55 ~ 200 °C · Minimum bend radius: 12.5 mm | Conductor: High-strength silver-plated alloy; Insulation / filler: LD-PTFE / PTFE insulation; PTFE filler and binder; Shield / jacket: Two 40 AWG high-strength alloy braids / white PFA | PDF ↓ |
| High-Speed I/O Parallel-Pair CablesCM-IO-PP | Communication Cables | 2 | Impedance: 100 ± 5 Ω · Operating temperature: −25 ~ 80 °C · Application: SFP+ / QSFP interconnect design; final link configuration depends on connector and length. | Dielectric: ePTFE / FEP; Shield / jacket: Copper foil PET / heat-bonded polyester tape | PDF ↓ |
| Star-Quad Ethernet CablesCM-QUAD-SQ | Communication Cables | 1 | Impedance: 100 ± 10 Ω · Operating temperature: −65 ~ 155 °C | Conductor / dielectric: Silver-plated stranded copper / ePTFE-PTFE; Shield / jacket: Tinned copper flat braid + tinned copper braid / FEP | PDF ↓ |
CM-COAX-PS-LW
Lightweight RF cable constructions using silver-plated copper-clad aluminium conductors and ePTFE / LD-PTFE insulation, in several sizes.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-PS-UF
Stranded-centre-conductor RF cables with low-density PTFE insulation and layered shielding, for routing that prioritises flexibility.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-PS-F
Single-centre-conductor coaxial cables with low-density PTFE insulation, for flexible RF routing within equipment and between instruments.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-CAT6A-4P
Four-pair Cat 6A cables with different conductor gauges and jacket configurations, selected around equipment-network, space and temperature requirements.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-STP
100 Ω and 120 Ω shielded twisted-pair options using fluoropolymer insulation and FEP jackets, for differential and bus connections.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-ASM-GP
RF assemblies based on phase-stable coaxial cable options, configured by both connectors, length and tolerance for instrument or equipment connections.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-ASM-TEST-RG
Phase-stable coaxial base cables with added mechanical protection, for instrument connections that need an external protective construction.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-1394B-SQ
110 Ω star-quad cables with ePTFE/PTFE insulation, double braid shielding and FEP jackets, for IEEE 1394b interconnect selection.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-HDMI
HDMI and HDMI 2.0 high-flex configurations with signal, control and power conductors specified separately for equipment connections.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-USB
USB 2.0, USB 3.0 and high-flex cable options, with signal, power and connector requirements selected separately.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-GLINK-SQ
24 AWG, 100 Ω star-quad bus cables with ePTFE/PTFE insulation and layered shielding, for GLink equipment interconnects.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-LVDS
Twisted-pair and parallel-pair LVDS cable options, with or without drain wires, for different layouts and grounding arrangements.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-LL
A 50 Ω microwave coaxial series with low-density or solid PTFE dielectric options, for interconnects with a defined transmission-loss budget.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-PREC
Miniature and low-delay coaxial constructions for compact RF connections, selected by dielectric, dimensions and the required cable configuration.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-SF
Semi-flexible coaxial constructions with model-specific insulation and jackets, selected around a defined route, installation space and terminations.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-COAX-PS-SR
50 Ω semi-rigid phase-stable coaxial constructions using a copper-alloy outer conductor and low-density PTFE insulation, in several sizes.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-1553B
24 AWG, 77 Ω bus cables with a PTFE insulation system, double alloy braid shielding and a PFA jacket.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-IO-PP
30 AWG and 32 AWG, 100 Ω parallel-pair constructions with ePTFE/FEP insulation, for high-speed I/O interconnect design.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗CM-QUAD-SQ
24 AWG, 100 Ω star-quad Ethernet cable construction with layered shielding and an FEP jacket, for equipment connections.
Models · Dimensions · Materials · Construction diagrams
Download bilingual PDF ↓View product information ↗Product dimensions and configuration are governed by the order specification. For other product information, contact CONMOLY.