conmoly 鑫聚新材
中文Contact us

CONMOLY

Technical Resources

Read cable selection guides and download bilingual basic specifications covering published dimensions, materials and model-specific entries.

Technical guides

Phase-Stable Coaxial Cables Compared

Compare CONMOLY’s lightweight, ultra-flexible and flexible 50 Ω coaxial cables by construction, dimensions and mass, with a model-specific selection example.

Cat6A Cable AWG Selection Guide

Compare current Cat6A base and S02 constructions by model, diameter, mass and temperature, without deriving link performance from conductor gauge.

QUICK SERIES REFERENCE

Documented cable & assembly series at a glance

Compare all 19 series with published model tables and bilingual PDFs. Select a series to view model-by-model outer diameters, conductor sizes and construction diagrams.

Series & CodeCategoryModelsPublished basic specificationsPrimary materialsDatasheet
Lightweight Phase-Stable Coaxial CablesCM-COAX-PS-LWCommunication Cables5Nominal impedance: 50 ΩConductor: Silver-plated copper-clad aluminium.; Dielectric: ePTFE / LD-PTFE.; Jacket: Fluoropolymer; FEP by default, with ETFE and other options according to environment.PDF ↓
Ultra-Flexible Phase-Stable Coaxial CablesCM-COAX-PS-UFCommunication Cables4Nominal impedance: 50 ΩCentre conductor: Regularly stranded silver-plated centre conductor.; Dielectric: Low-density PTFE insulation.; Outer conductor and shield: Silver-plated flat conductor and braided shield.PDF ↓
Flexible Phase-Stable Coaxial CablesCM-COAX-PS-FCommunication Cables7Nominal impedance: 50 ΩCentre conductor: Solid silver-plated centre conductor.; Dielectric: Low-density PTFE insulation.; Outer conductor and shield: Silver-plated flat conductor and braided shield.PDF ↓
Cat 6A Ethernet CablesCM-CAT6A-4PCommunication Cables8Nominal impedance: 100 ΩStandard model constructions: Models without S02 suffix: silver-plated copper, ePTFE/PTFE insulation, individual foil shields and overall braid, fluoropolymer jacket.; Additional configurations: S02 jacket and shielding are specified per order; refer to the separate temperature and mass table.PDF ↓
Shielded Twisted-Pair CablesCM-STPCommunication Cables14Operating temperature: −55 ~ 200 °C · Nominal impedance: 100 Ω / 120 ΩConductor: Silver-plated copper or alloy, according to construction.; Dielectric: ePTFE / PTFE; Shield / jacket: Silver-plated copper braid / FEPPDF ↓
Phase-Stable RF Cable AssembliesCM-COAX-ASM-GPCable Assemblies10Nominal impedance: 50 Ω · Ordering: Select the cable configuration, connector at each end, length and tolerance. Dimensions below describe the cable, not an assembled connector.Dielectric: Low-density PTFE; Conductor: Solid or stranded silver-plated conductor, by configuration.; Jacket: PFA, FEP or TPU, by configuration.PDF ↓
Armoured RF Cable AssembliesCM-COAX-ASM-TEST-RGCable Assemblies2Ordering: Connector pair, length and tolerance are specified per order.OD6P50 protection: SUS304 spring, stainless-steel braid, FEP wraps and PTFE filament braid.; Base cable: Low-density PTFE insulated, shielded phase-stable coaxial cable.PDF ↓
IEEE 1394b Aviation Data-Bus CablesCM-1394B-SQCommunication Cables5Nominal impedance: 110 ΩConductor: Silver-plated copper, star-quad construction.; Insulation: ePTFE / PTFE.; Shielding: Dual silver-plated copper braids.PDF ↓
HDMI CablesCM-HDMICommunication Cables2High-flex construction: HDMI 2.0; −25 ~ 80 °C; minimum bend radius 6 × ODHigh-flex signal pairs: Silver-plated copper alloy; ePTFE/PFA insulation; aluminium foil pair shields.; High-flex control conductors: 30 AWG (41/46), with Hytrel insulation.; High-flex overall shield / jacket: Tinned copper braid / black PVC.PDF ↓
USB 2.0 / USB 3.0 CablesCM-USBCommunication Cables7USB 3.0 OD5P20 / HF-OD5P20 temperature: −25 ~ 80 °C · Connector configuration: USB connector type, pin assignment and cable length are specified per order.USB 3.0 OD5P20: FEP jacket; 26 AWG signal / power, 28 AWG USB 2.0 pair.; USB 3.0 HF-OD5P20: TPU jacket; 28 AWG signal, 30 AWG USB 2.0 pair, 22 AWG power.PDF ↓
GLink Bus CablesCM-GLINK-SQCommunication Cables1Nominal impedance: 100 ΩConductors: Silver-plated copper strands.; Insulation: ePTFE / PTFE; low-density PTFE separating tape.; Shield: Silver-plated copper tape and braided conductor layers.PDF ↓
LVDS Differential CablesCM-LVDSCommunication Cables17Nominal impedance: 100 ΩConductors: Silver-plated copper; gauge and stranding vary by model.; Insulation: ePTFE / PTFE.; Shield and drain: Braided conductor or aluminium composite tape; drain wire by construction.PDF ↓
Low-Loss Microwave Coaxial CablesCM-COAX-LLCommunication Cables9Nominal impedance: 50 ΩDielectric: Low-density PTFE; solid PTFE for OD4P70.; Shielding: Metal tape and braided shielding; construction depends on model.PDF ↓
Precision Coaxial CablesCM-COAX-PRECCommunication Cables8Nominal impedance: 50 Ω; OD1P70: 51 Ω · Low-delay constructions: 4.3 ns/m (OD1P40 / OD1P80 / OD2P05)Dielectric: ePTFE/FEP, FEP or low-density PTFE, depending on construction.; Shielding: Silver-plated copper tape and/or braid, depending on model.PDF ↓
Semi-Flexible Coaxial CablesCM-COAX-SFCommunication Cables6Nominal impedance: 50 ΩS01 insulation / jacket: Fluoropolymer; Other constructions: Solid PTFE insulation; OD2P90 uses PVC jacket, other listed constructions use FEP.PDF ↓
Semi-Rigid Phase-Stable Coaxial CablesCM-COAX-PS-SRCommunication Cables4Nominal impedance: 50 Ω · Listed cutoff frequency: 40 GHz · Operating temperature: −65 ~ 250 °CCentre conductor: Silver-plated copper alloy; Dielectric: Low-density PTFE; Outer conductor: Copper alloyPDF ↓
1553B Data Bus CablesCM-1553BCommunication Cables1Impedance: 77 ± 5 Ω · Operating temperature: −55 ~ 200 °C · Minimum bend radius: 12.5 mmConductor: High-strength silver-plated alloy; Insulation / filler: LD-PTFE / PTFE insulation; PTFE filler and binder; Shield / jacket: Two 40 AWG high-strength alloy braids / white PFAPDF ↓
High-Speed I/O Parallel-Pair CablesCM-IO-PPCommunication Cables2Impedance: 100 ± 5 Ω · Operating temperature: −25 ~ 80 °C · Application: SFP+ / QSFP interconnect design; final link configuration depends on connector and length.Dielectric: ePTFE / FEP; Shield / jacket: Copper foil PET / heat-bonded polyester tapePDF ↓
Star-Quad Ethernet CablesCM-QUAD-SQCommunication Cables1Impedance: 100 ± 10 Ω · Operating temperature: −65 ~ 155 °CConductor / dielectric: Silver-plated stranded copper / ePTFE-PTFE; Shield / jacket: Tinned copper flat braid + tinned copper braid / FEPPDF ↓

CM-COAX-PS-LW

Lightweight Phase-Stable Coaxial Cables

Lightweight RF cable constructions using silver-plated copper-clad aluminium conductors and ePTFE / LD-PTFE insulation, in several sizes.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-PS-UF

Ultra-Flexible Phase-Stable Coaxial Cables

Stranded-centre-conductor RF cables with low-density PTFE insulation and layered shielding, for routing that prioritises flexibility.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-PS-F

Flexible Phase-Stable Coaxial Cables

Single-centre-conductor coaxial cables with low-density PTFE insulation, for flexible RF routing within equipment and between instruments.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-CAT6A-4P

Cat 6A Ethernet Cables

Four-pair Cat 6A cables with different conductor gauges and jacket configurations, selected around equipment-network, space and temperature requirements.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-STP

Shielded Twisted-Pair Cables

100 Ω and 120 Ω shielded twisted-pair options using fluoropolymer insulation and FEP jackets, for differential and bus connections.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-ASM-GP

Phase-Stable RF Cable Assemblies

RF assemblies based on phase-stable coaxial cable options, configured by both connectors, length and tolerance for instrument or equipment connections.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-ASM-TEST-RG

Armoured RF Cable Assemblies

Phase-stable coaxial base cables with added mechanical protection, for instrument connections that need an external protective construction.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-1394B-SQ

IEEE 1394b Aviation Data-Bus Cables

110 Ω star-quad cables with ePTFE/PTFE insulation, double braid shielding and FEP jackets, for IEEE 1394b interconnect selection.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-LVDS

LVDS Differential Cables

Twisted-pair and parallel-pair LVDS cable options, with or without drain wires, for different layouts and grounding arrangements.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-LL

Low-Loss Microwave Coaxial Cables

A 50 Ω microwave coaxial series with low-density or solid PTFE dielectric options, for interconnects with a defined transmission-loss budget.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-PREC

Precision Coaxial Cables

Miniature and low-delay coaxial constructions for compact RF connections, selected by dielectric, dimensions and the required cable configuration.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-SF

Semi-Flexible Coaxial Cables

Semi-flexible coaxial constructions with model-specific insulation and jackets, selected around a defined route, installation space and terminations.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-COAX-PS-SR

Semi-Rigid Phase-Stable Coaxial Cables

50 Ω semi-rigid phase-stable coaxial constructions using a copper-alloy outer conductor and low-density PTFE insulation, in several sizes.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

CM-IO-PP

High-Speed I/O Parallel-Pair Cables

30 AWG and 32 AWG, 100 Ω parallel-pair constructions with ePTFE/FEP insulation, for high-speed I/O interconnect design.

Models · Dimensions · Materials · Construction diagrams

Download bilingual PDF ↓View product information ↗

Product dimensions and configuration are governed by the order specification. For other product information, contact CONMOLY.