CONMOLY
LVDS Cable Selection: Twisted Pair or Parallel Pair?
An LVDS cable choice should start with the equipment’s signal and termination requirements. Twisted-pair and parallel-pair entries describe different physical constructions; the geometry label alone does not establish which will meet an installed link’s acceptance limits. Match the connector layout, routing envelope and shielding plan before comparing individual models.
Read the full construction code
CONMOLY’s LVDS cable page currently lists 17 configurations: eight twisted-pair entries, six parallel-pair entries without drain wire and three parallel-pair entries with drain wire. Keep the TP, PP-ND and PP-DW distinctions as well as AWG, stranding and suffix. A drain arrangement should be checked for the selected construction rather than inferred for the entire family.
Compare geometry using named examples
| Code | Conductor (AWG / stranding) | Overall dimensions (mm) | Mass (g/m) |
|---|---|---|---|
| CM-LVDS-TP-AWG28-S01 | 28 (7/36) | 2.10 × 1.70 | 10 |
| CM-LVDS-PP-ND-AWG28-S01 | 28 (7/36) | 3.05 × 2.11 | 16 |
| CM-LVDS-PP-DW-AWG28-S01 | 28 (19/40) | 2.25 × 1.40 | 6 |
These three examples have the same AWG label but different stranding, dimensions or mass. They are useful for a mechanical comparison, not proof of equivalent electrical behaviour. Check both width and thickness against the actual connector and routing envelope. Preserve the published qualifiers when another model lists tolerances or maximum values.
Keep shielding and drain termination explicit
- Identify the connector pinout and the required signal-pair orientation.
- Specify the shield termination method and any drain-wire requirement.
- Check available space for the cable profile and termination.
- Define the routed length, bends and any repeated movement.
- Identify the signal conditions and acceptance evidence for the complete link.
The presence of a drain wire is a construction and termination choice. It is not a universal performance ranking. Likewise, a parallel or twisted geometry does not by itself establish a maximum usable frequency or data rate for every cable and connector arrangement.
Keep detailed values with the model they describe
For example, the current CM-LVDS-PP-ND-AWG24-S01 entry lists 3.95 ± 0.10 × 2.65 ± 0.075 mm dimensions and ≤30 g/m mass. Its model detail lists 100 ± 10 Ω impedance, ≤43 pF/m capacitance, ≤4.5 ns/m propagation delay and an engineering-use temperature range of −55 to +200 °C. These entries belong to that named configuration, not to all 17 options.
Do not transfer those limits to the AWG28 examples above or infer an environmental qualification from the temperature entry. The harsh-environment signal guide helps collect the remaining system and environmental inputs.
FAQ: Is a parallel pair always a better mechanical fit?
Compare the named model’s width, thickness and termination with the installation. The geometry label alone does not answer that question.
FAQ: Can nominal 100 Ω establish a compatible link?
Impedance is one requirement. The equipment interface, signal conditions, connector arrangement, length and acceptance method must also match.
FAQ: How should I propose a replacement construction?
Provide the existing code and drawing, required termination and the attributes that may change through the contact page. Use the data bus family chooser if the interface family is still open, then agree the sample comparison conditions.