IEEE 1394b Aviation Cable: A Selection Checklist

Published / updated:

An IEEE 1394b cable enquiry for an aviation application needs both the interface definition and the programme’s installation requirements. A family name or application label is not an approval record. Start with the controlled system documents, the proposed cable code and the finished termination before comparing candidates.

Identify the current dimensioned constructions

CONMOLY’s IEEE 1394b cable page lists the following three dimensioned models. The published construction uses silver-plated copper conductors, ePTFE / PTFE insulation, dual silver-plated copper braid shielding and a blue FEP jacket. Confirm the selected row against the connector entry and actual route.

CodeConductor (AWG)Overall diameter (mm)Max. mass (g/m)
CM-1394B-SQ-AWG2626≤4.25≤40
CM-1394B-SQ-AWG24244.955.8
CM-1394B-SQ-AWG22225.40 ± 0.20≤62

The same product page also lists additional AWG28 and AWG30 attenuation entries. Those are not complete mechanical or environmental specifications. Identify which published fields exist for the exact candidate instead of filling missing dimensions from another AWG.

Keep the detailed values model-specific

ModelImpedanceTemperature range
CM-1394B-SQ-AWG22110 +6/−4 Ω−65 ~ +200 °C
CM-1394B-SQ-AWG26110 ± 6 Ω−55 ~ +200 °C

These are entries for the named cable models. They should not be collapsed into one temperature range or impedance tolerance for every 1394b option. They also do not establish the temperature rating of a connector assembly or prove completion of a programme’s environmental tests. The temperature guide explains that boundary.

Provide the signal and installation definition

  • Equipment interface, operating mode and the applicable document revision.
  • Required conductor arrangement, pinout and connector references.
  • Installed length, supports, bends and any movement.
  • Shield termination, marking and traceability requirements.
  • Temperature exposure and other environmental conditions.
  • System acceptance method and required sample evidence.

A supported link length cannot be established from a diameter table or a single attenuation point alone. Keep any required length and signal mode as project inputs, and evaluate the proposed cable, connectors and equipment together. See the harsh-environment signal cable guide for the wider review sheet.

Separate cable selection from programme approval

Identify any mandatory cable, interface or environmental standard by its actual revision. State the required test configuration, sample identification, records and approving party. A construction description can support an engineering shortlist; compliance and qualification require the relevant evidence.

For a replacement, retain the controlled baseline and identify every difference that matters to termination or system performance. Use the quotation and sample validation guide to compare a proposed alternative on the agreed basis.

FAQ: Does “aviation cable” mean an approved installation?

No. The application description does not establish a programme approval or airworthiness status.

FAQ: Can AWG22 values be used for AWG26?

Use each model’s own published entries. Their listed impedance tolerance and lower temperature endpoint already differ.

FAQ: What should accompany a 1394b enquiry?

Provide the system definition, cable and connector drawing, route and acceptance conditions through the contact page. If the interface is not fixed, use the data bus family chooser before selecting an AWG.