Lightweight vs Ultra-Flexible vs Flexible Phase-Stable Coaxial Cables

Published / updated:

Choosing a phase-stable coaxial cable starts with the interconnect requirements: operating frequency, impedance, length, interfaces, temperature and installation conditions. CONMOLY’s lightweight, ultra-flexible and flexible series provide three constructions to compare using the published model dimensions and mass.

The current series tables contain 16 models: five lightweight, four ultra-flexible and seven flexible. All three series list a nominal impedance of 50 Ω. This guide compares their published construction data and uses one approximately 3.6 mm example to show how to read model-specific information.

What the three series names describe

SeriesListed modelsCentre-conductor constructionListed diameter range (mm)
Lightweight — CM-COAX-PS-LW5Silver-plated copper-clad aluminium2.2–7.3
Ultra-flexible — CM-COAX-PS-UF4Stranded, silver-plated centre conductor2.2–7.4
Flexible — CM-COAX-PS-F7Solid, silver-plated centre conductor1.46–8.1

The diameter ranges summarize entries in the current series tables; use the selected model’s dimensions and any stated tolerances for mechanical design. The lightweight series lists an ePTFE / LD-PTFE dielectric. The ultra-flexible and flexible series list low-density PTFE insulation.

The family names help organize the comparison, but they do not replace model-specific loss, phase or mechanical requirements. In particular, “ultra-flexible” does not by itself establish a minimum installation radius, repeated-flex life or allowable phase change for an assembly.

Define the application before comparing dimensions

For an RF component, fixture or test-system interconnect, collect the following requirements before shortlisting a model:

  • Operating frequency or frequency band, required impedance and allowable cable or assembly loss.
  • Required length, connector interfaces and available routing space.
  • Operating-temperature conditions and any environmental acceptance requirements.
  • Whether the cable stays in a fixed route, is repositioned occasionally or moves repeatedly.
  • Project limits for diameter and mass, plus any phase or reflection acceptance criteria.

Then compare the constructions that could fit those requirements. A diameter-first rule can overlook a frequency, interface or environmental constraint. For a broader discussion of the trade-offs, read RF interconnect selection: balancing loss, size, mass and flexibility.

A model comparison at approximately 3.6 mm diameter

The three series each contain a model with an OD3P60 code. The table below retains the dimensions, tolerances and mass notation in the current product tables. The shared size label does not establish that the three models have interchangeable electrical or mechanical ratings.

ModelCentre conductor (mm)Overall diameter (mm)Mass (g/m)
CM-COAX-PS-LW-OD3P600.914 ± 0.0083.60 ± 0.10≤23
CM-COAX-PS-UF-OD3P600.93.631
CM-COAX-PS-F-OD3P600.913.632

For a mass-constrained design, the lightweight entry provides a lower listed mass than the two other entries at this size. Keep the ≤ sign: its 23 g/m value is an upper limit, while 31 and 32 g/m are reproduced as listed without adding an unprovided maximum or tolerance. Check the selected configuration before using any value as an acceptance requirement.

The published CM-COAX-PS-LW-OD3P60 model entry also gives 50 ± 2 Ω impedance, capacitance ≤85 pF/m, a 17.5 mm minimum bend radius and an operating range of −55 to +165 °C. The bend-radius and temperature figures are engineering-use data; they do not establish repeated-flex life or full-temperature test results. They are specific to that model and must be checked against the intended jacket and termination configuration.

Compare loss at the required frequency and under stated conditions

Use attenuation information for the selected model, frequency and measurement conditions. Distinguish a typical value, a maximum specification and a measured result from a particular sample. A cable-only figure is not a completed-assembly loss guarantee.

An attenuation-per-unit-length value can support a cable-only length estimate when its conditions apply. Connector and termination effects still need to be considered for the completed assembly. Do not attribute a loss difference solely to a stranded or solid conductor when other construction details and test conditions also differ.

Separate bending behaviour, temperature effects and assembly limits

For a fixed installation, define the installed bend geometry and how it is checked. For repeated movement, define the radius, motion, cycle count, measurement conditions and acceptance limits. A listed minimum bend radius does not establish performance under every movement pattern.

Mechanical bending and temperature exposure are separate validation questions. Read bending stability versus temperature phase stability when preparing a phase-validation plan.

Similarly, a material temperature range does not set the operating-temperature rating of a cable or its connectors and terminations. Use the model and configuration requirements discussed in PTFE material temperature versus cable temperature.

Review the series data and discuss the selected configuration

Use the current product pages and bilingual basic datasheets to review the listed models, dimensions and materials. Compare any additional electrical or environmental requirements against the selected configuration and its applicable specification.

For a technical review or quotation, send the model or reference drawing, length, interfaces, frequency, environmental conditions, installation requirements, quantities and requested tests through the contact section. The technical resource library contains the current series documents and related selection guides.

What is the main difference between the three phase-stable cable series?

Their published centre-conductor constructions differ: lightweight uses silver-plated copper-clad aluminium, ultra-flexible uses a stranded silver-plated centre conductor, and flexible uses a solid silver-plated centre conductor. All three series list a nominal impedance of 50 Ω. Construction is a starting point; select the exact model against the application requirements.

Which series has the lowest listed mass at approximately 3.6 mm diameter?

For the three models in the comparison above, the lightweight entry is ≤23 g/m, the ultra-flexible entry is 31 g/m and the flexible entry is 32 g/m. These entries retain the notation in the current product tables. Do not turn the comparison into a fixed weight-saving percentage or a mass guarantee for another model.

Does a minimum bend radius establish repeated-flex life or phase stability?

No. A minimum bend radius alone does not define a cycle-life or phase-stability rating. State the installed geometry, movement, cycle conditions, frequency and acceptance limits for the selected cable and assembly.

Can one operating-temperature range be used for all three series?

Use the limit for the selected model and configuration. The published CM-COAX-PS-LW-OD3P60 entry lists −55 to +165 °C as engineering operating data. It does not establish the same range for other models or prove full-temperature testing of a completed assembly.

What should I send for cable selection or a quotation?

Send the model or reference drawing, operating frequency, cable length, connector interfaces, temperature conditions, installation or movement requirements, quantities and required acceptance tests. Use the contact section to discuss the requirements.