How to Specify a Custom RF Cable Assembly
A custom RF cable assembly enquiry is easier to compare when every supplier is reviewing the same finished configuration. “Phase-stable cable, one metre, SMA” leaves the connector details, length datum, routing and acceptance test open. A short drawing and a structured requirement sheet provide a stronger starting point.
Define both ends and the controlled length
- Identify connector A and B by interface, gender, orientation and the required part reference where available.
- Define the finished-length datum and tolerance on a drawing.
- Add any angular orientation, backshell, marking and strain-relief requirements.
- Show the installed route, space restrictions and sections that will move.
Connector family names do not by themselves establish the permitted operating band of the finished assembly. The mating interface, selected part, cable termination and measured configuration need to be reviewed together. Identify any mandatory customer-supplied connector or approved-parts restriction at the enquiry stage.
Use published cable dimensions for mechanical screening
The following selected configurations come from CONMOLY’s general-purpose assembly page. The diameter and mass figures describe the cable portion. They are not overall connector dimensions or complete-assembly mass. The connector combination, length and tolerance are order-specific.
| Configuration | Centre conductor (mm) | Cable diameter (mm) | Mass (g/m) |
|---|---|---|---|
| CM-COAX-ASM-PS-OD0P94 | 0.203 | 0.94 ± 0.05 | 3.5 |
| CM-COAX-ASM-PS-OD3P60 | 0.914 | 3.60 ± 0.10 | 33 |
| CM-COAX-ASM-PS-OD4P80 | 1.372 | 4.80 ± 0.20 | 56 |
These examples are mechanically different starting points. A shared nominal impedance does not make their loss, phase behaviour, installed bend conditions or connector options interchangeable. Check the configuration that the drawing actually requires.
State the electrical requirement and its measurement boundary
| Field | What to state |
|---|---|
| Frequency and impedance | Operating band and required impedance |
| Insertion loss | Limit versus frequency for the finished assembly |
| Reflection requirement | Return loss or VSWR, frequencies and reference planes |
| Phase requirement | Matching or stability, conditions and acceptance metric |
| Evidence | Required traces, report identifiers and sample configuration |
Keep insertion loss and reflection requirements distinct. If phase stability matters, separate movement from temperature and specify each sequence. A loss-budget worksheet and the phase stability introduction can help define these inputs.
Agree the sample decision before comparing prices
List the number of samples required, requested documentation, acceptance conditions and who will review the results. Identify which tests are requested for a sample and which records are needed for later orders. Any test provision, lead time, minimum order quantity or reporting format should be confirmed for the proposed order rather than inferred from this checklist.
For an existing-part replacement, also provide the controlled drawing revision, available baseline results and the attributes that must remain comparable. See quotation and sample validation for the comparison sequence.
FAQ: Is an interface name enough to select the connectors?
It is a starting point. Gender, orientation, part restrictions, mating details and termination requirements still need review.
FAQ: Can a cable datasheet replace an assembly test?
It can support the cable shortlist. Finished connectors, length and termination introduce assembly-specific requirements that need their own acceptance basis.
FAQ: How do I start a configuration review?
Send the drawing and requirement sheet through CONMOLY’s contact page. Keep open items identified so that the proposed configuration and quotation can state their assumptions clearly.